Abstract
This paper presents the results of an advanced turbine blade test program aimed at improving turbine blade low cycle fatigue (LCF) life. A total of 21 blades were tested in a blade thermal tester. The blades were made of MAR-M-246(Hf)DS and PWA-1480SC in six different geometries. The test results show that the PWA-1480SC material improved life by a factor of 1.7 to 3.0 over the current MAR-M-246(Hf)DS. The geometry changes yielded life improvements as high as 20 times the baseline blade made of PWA-1480SC and 34 times the baseline MAR-M-246DS blade.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.