Abstract

Thermodynamic equilibrium calculation relating fuel chemistry with flue-gas composition and volatile condensate deposits on tube metals upon combustion of various “dirty” fuel was conducted for a better understanding of the deposit chemistry of superheater tubes in steam-generating boilers. Corrosive impurities such as sodium, potassium, chlorine, and sulfur, inevitably involved in fuel, were considered in the calculation. Possible influence of flue-gas temperature on deposit chemistry was investigated as well. Based on the flue-gas composition and the deposit chemistry, corrosion environments of steam-generating boilers firing various “dirty” fuel were discussed.