Abstract

A series of systematic tests have been carried out on the superconducting electron cyclotron resonance ion source SCECRIS at the Michigan State University National Superconducting Cyclotron Laboratory in order to better understand the role of different parameters which determine the performance of these sources. A relevant part of these tests has been focused on the role of magnetic field and microwave frequency, with the goal of demonstrating the capability of low frequency electron cyclotron resonance ion sources to produce high ion charge states, in spite of their relative low plasma density. This goal can be achieved using a very high magnetic confining field, according to the concept of a high B mode. A comparison of the source performance at 2.45 and 6.4 GHz for different levels of magnetic field is described in this article.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.