Abstract

The irradiation resistance of tungsten (W) and a high-entropy alloy-based material W0.5(TaTiVCr)0.5 was analysed using depth marker implantation (F3+ ions irradiation). Mirror-polished W and W0.5(TaTiVCr)0.5 samples were exposed to 5.0 MeV and 4.2 MeV, respectively, F3+ ions up to a maximum fluence of 3.2x1012 ions/cm2. The scanning electron and atomic force microscopy of implanted W showed nanostructured features and pinholes, respectively, whereas the surface of implanted W0.5(TaTiVCr)0.5 remained fairly smooth. The nanoindentation hardness of W and W0.5(TaTiVCr)0.5 increased from 6.6 GPa to 8.5 GPa and from 13.9 GPa to 16.3 GPa, respectively, due to implantation. The ion implantation induced lattice defects and compressive stress, as a result, the BCC peaks of W and W0.5(TaTiVCr)0.5 moved to higher Bragg angles. The irradiation induced strain in W0.5(TaTiVCr)0.5 (4.4x10-4) remained lower than that in pure W (8.5x10-4). The comparison of W and W0.5(TaTiVCr)0.5 suggested the higher resistance of W0.5(TaTiVCr)0.5 to high energy ion implantation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.