Abstract

Mixed stimulation programs (MIX) that switch from constant frequency trains (CFT) to variable frequency trains have been proposed to offset the rapid fatigue induced by CFT during electrical stimulation. However, this has never been confirmed with long stimulation patterns, such as those used to evoke functional contractions. The purpose of this study was to test the hypothesis that MIX programs were less fatiguing than CFTs in strength training-like conditions (6-s contractions, 30-min). Thirteen healthy subjects underwent 2 sessions corresponding to MIX and CFT programs. Measurements included maximal voluntary isometric torque and torque evoked by each contraction. There were greater decreases of voluntary and evoked torque (P < 0.05) after CFT than MIX, and mean torque was 13 ± 1% higher during the MIX session (P < 0.05). These findings confirm that combining train types might be a useful strategy to offset rapid fatigue during electrical stimulation sessions with long-duration contractions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.