Abstract
Based on an acoustic logging transmission network and the engineering pattern of a sliding wave in acoustic logging, analysis and calculations have been performed in a study of the effects of the electric-acoustic and acoustic-electric conversions of the transducers on the acoustic logging signal. The results show that acoustic-electric conversion through the transducer can cause not only a serious disturbance in the signal amplitude, but also an apparent transmission delay. For engineering applications, the amplitude variation and transmission delay must be accounted for in a practical analysis of the acoustic logging signal in rocks. The results also show that with enhanced understanding and proper justification, the error caused by the acoustic-electric conversion can be significantly reduced in evaluation of the cement bond quality of a cased well, and the accuracy of rock porosity calculated using the measured acoustic velocity can be increased.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.