Abstract

PurposeUltraprotective ventilation in acute respiratory distress syndrome (ARDS) patients with veno-venous extracorporeal membrane oxygenation (VV ECMO) reduces mechanical power (MP) through changes in positive end-expiratory pressure (PEEP); however, the optimal approach to titrate PEEP is unknown. This study assesses the effects of three PEEP titration strategies on MP, hemodynamic parameters, and oxygen delivery in twenty ARDS patients with VV ECMO. Material and methodsPEEP was titrated according to: (A) a PEEP of 10 cmH2O representing the lowest recommendation by the Extracorporeal Life Support Organization (PEEPELSO), (B) the highest static compliance of the respiratory system (PEEPCstat,RS), and (C) a target end-expiratory transpulmonary pressure of 0 cmH2O (PEEPPtpexp). ResultsPEEPELSO was lower compared to PEEPCstat,RS and PEEPPtpexp (10.0 ± 0.0 vs. 16.2 ± 4.7 cmH2O and 17.3 ± 4.0 cmH2O, p < 0.001 each, respectively). PEEPELSO reduced MP compared to PEEPCstat,RS and PEEPPtpexp (5.3 ± 1.3 vs. 6.8 ± 2.0 and 6.9 ± 2.3 J/min, p < 0.001 each, respectively). PEEPELSO resulted in less lung stress compared to PEEPCstat,RS (p = 0.011) and PEEPPtpexp (p < 0.001) and increased cardiac output and oxygen delivery (p < 0.001 each). ConclusionsAn empirical PEEP of 10 cmH2O minimized MP, provided favorable hemodynamics, and increased oxygen delivery in ARDS patients treated with VV ECMO. Trial registrationGerman Clinical Trials Register (DRKS00013967). Registered 02/09/2018https://drks.de/search/en/trial/DRKS00013967