Abstract

The aim of this study was to compare the effect of different kinds of surgical meshes on postoperative adhesion formation. Forty-two New Zealand White rabbits were studied. The rabbits were grouped into six groups, according to the type of surgical meshes (Prolene, Mersilene, Vypro, polytetraflouroethylene (PTFE), Proceed and control group) implanted into the peritoneum cavity. Thirty days after the operation, the relaparotomies were carried out, and any adhesions observed between the implanted mesh and tissues were evaluated and graded. The mean adhesion degree was 9.2 in the Mersilene mesh group, 9.5 in the Prolene mesh group, 9.7 and in the Vypro mesh group (P > 0.05). The mean adhesion degree was 1 in the control group, 2.75 in the Proceed mesh group and 2.25 in the PTFE mesh group. There was a significant difference in adhesion degree between the control, Proceed and PTFE groups and the Prolene, Mersilene and Vypro mesh groups. The adhesion degree was significantly lower in the Proceed and PTFE mesh groups when comparing them with the Prolene, Mersilene and Vypro meshes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.