Abstract

In many industrial applications, heat loads management requires the design and production of compact heat exchangers which are expected to handle high thermal loads with acceptable pressure losses, while assuring good mechanical performances. These challenging targets can be achieved by filling the cavities where the cool/hot fluid circulates with lattice structures promoting the heat exchange between the fluid and the cavity boundaries. Such lattice structures can be only produced through Additive Manufacturing due to their high geometric complexity. Recent experimental investigations proved the effectiveness of some kinds of lattice structures having a circular cross section. Here the aerothermal behaviour of Body-Centred Cubic (BCC) lattice stagger arrays in a rectangular channel was experimentally investigated by considerably extending the previous studies to higher Reynolds numbers (up to 30′000) and to new types of lattice structures. Specifically, three new BCC structures having a cam-like, drop-like and elliptical cross section were explored in this work and compared against those having circular cross section. All the samples were manufactured by means of Laser Powder Bed Fusion and made from AlSi10Mg. At first, the heat exchangers were comprehensively characterized by means of optical non-destructive methods. Successively they were tested in a dedicated rig by imposing constant heat flux boundary conditions. The characteristics of the transitional or fully turbulent approaching flow to the test section are also reported thanks to dedicated flow field measurements performed by Particle Image Velocimetry. According to the obtained results, the BCC structure with the circular cross section of larger diameter is the most effective in terms of heat transfer, although it is largely penalized by the pressure losses. Similar heat transfer performances were achieved by the tapered cross section of elliptical shape with the advantage of a considerably lower friction factor. Pressure losses resulted almost identical for all the tapered cross sections but lower than those of the circular one having an equal frontal dimension. When considering the thermal performance factor the circular shape becomes unfavourable for Re>20′000, while the elliptical cross section is the best choice to efficiently promote heat transfer up to Re=30′000.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call