Abstract

Little attention has been given to the effects of reuse on the permeability of low-flux membranes, especially regarding middle molecules. We studied two different types of low-flux membranes at reuses 0, 6, and 12 in five patients undergoing hemodialysis with the following combinations of membrane and sterilant: cellulose diacetate membrane and formaldehyde, polysulfone membrane and formaldehyde, cellulose diacetate membrane and peracetic acid, and polysulfone and peracetic acid. The permeability of the membranes was assessed through the hydraulic ultrafiltration coefficient (KUF ), sieving coefficient for β2 -microglobulin (B2M), and vitamin B12 and albumin concentrations in ultrafiltrate. After 12 reuses, total cell volume (TCV) tended to be reduced in both cellulose diacetate and polysulfone dialyzers irrespective of the sterilant used, but significance was only found for the first set of dialyzers. Cellulose diacetate dialyzers reprocessed with either formaldehyde or peracetic acid showed an important reduction in KUF (31% [P < 0.05] and 23% [P < 0.05], respectively). A significant elevation in KUF was found in polysulfone membranes reprocessed with peracetic acid (41%; P < 0.05), but no alterations in KUF were found in polysulfone membranes reprocessed with formaldehyde. Cellulose diacetate membranes were intrinsically more permeable to B2M than polysulfone membranes (sieving coefficient, 6.85 ± 2.53 versus 0.04 ± 0.02 × 10–2; P < 0.001), which was not modified by any of the sterilants. Vitamin B12 levels in ultrafiltrate decreased to an undetectable level in four of five samples collected after 12 reuses in polysulfone membranes reprocessed with peracetic acid (90 ± 71 to 3 ± 8 pg/mL; P < 0.05 versus reuse 0). Albumin leakage occurred in two of five samples after the 12th reuse, but only in polysulfone membranes reprocessed with peracetic acid. Our findings suggest that reuse of low-flux polysulfone dialyzers reprocessed with peracetic acid is associated with structural damage of the membrane and a reduced permeability to middle molecules.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.