Abstract
The influence of various diagonal-bracings arrangements on the heat transfer coefficient of wooden walls was studied with the goal of improving the thermal insulation performance of the walls. Through the reliability verification of the theoretical value of the heat transfer coefficient, this study found that a larger proportion of wood frame area resulted in larger theoretical and test values for the heat transfer coefficient. The heat transfer coefficient of the wall with expanded polystyrene foam sheet (EPS) was 5.90% to 6.10% higher than that with extruded polystyrene foam sheet (XPS), and the tested value was 4.75% to 8.60% higher. The maximum value of the average heat transfer coefficient of 12 diagonal-braced walls was 0.366 W·m-2·K-1, which met the thermal level of the severe cold area. The test value of the heat transfer coefficient was larger than the theoretically calculated value, and the linear correlation was up to 0.978.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.