Abstract
Statement of problemThe clinical performance of implant-retained overdentures (IODs) with plastic bar clips made of different materials in the same design and dimensions may vary according to the patient’s daily home care procedures. However, information about the effects of denture cleaning solutions on the retention of Hader bar clips is lacking. PurposeThe purpose of this in vitro study was to evaluate the retention of Hader bar clips made of different polymers after being soaked in denture cleaning solutions. Material and methodsNinety Hader bar clips made of polyamide (PA, n=30), polytetrafluoroethylene (PTFE, n=30), and polyetherketoneketone (PEKK, n=30) materials were tested. Two multiunit abutments were screwed onto the implant analogs and embedded into an acrylic resin block in a standardized position. The digital scanning of the abutments was acquired, and the bar patrix of each material system milled from a cobalt-chromium (Co-Cr) alloy disk by using computer-aided design and computer-aided manufacturing (CAD-CAM). After the milled bar patrices were screwed onto abutments and the metal housings of the bar clips were embedded into acrylic resin blocks, they were connected passively at the same angulation to a universal testing machine. The initial retention values of all Hader bar clips were measured, and each material system was divided into 3 subgroups (n=10) before soaking in the cleaning solutions: distilled water (DW), 5% sodium hypochlorite (NaOCl), or sodium bicarbonate-sodium perborate (SBSP). Each material was soaked for the equivalent of 3 months of clinical use. The final retention values of each Hader bar clip were measured. The data were statistically analyzed by using a 2-way analysis of variance (ANOVA), the Tukey honestly significant difference (HSD) test, and the paired sample t test (α=.05). ResultsThe 2-way ANOVA showed that the denture cleaning solution, the clip material, and their interactions led to significantly different retention values (P<.001). A decrease was observed for the retention values of all test groups after soaking in the cleaning solutions (P<.05). No retention was observed for the PTFE clips after soaking in the 5% NaOCI solution. ConclusionsThe denture cleaning solutions negatively affected the retention of Hader bar clips, regardless of the type of solution and clip material. The 5% NaOCI solution not only decreased the retention of PTFE clips but also completely degraded it. It is recommended that 5% NaOCI solution be avoided for the daily care of IODs with PTFE clips.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.