Abstract

The effectiveness of high-frequency chest wall oscillation (HFCWO) in mucolysis and mucous clearance is thought to be dependant on oscillatory flow rate (Fosc). Therefore, increasing Fosc during HFCWO may have a clinical benefit. To examine effects of continuous positive airway pressure (CPAP) on Fosc at two oscillation frequencies in healthy subjects and patients with airway obstruction. Five healthy subjects and six patients with airway obstruction underwent 12 randomized trials of HFCWO (CPAP levels of 0 cm H2O, 2 cm H2O, 4 cm H2O, 6 cm H2O, 8 cm H2O and 10 cm H2O at frequencies of 10 Hz and 15 Hz) within a body plethysmograph, allowing measurements of changes in lung volume. Fosc was measured by reverse plethysmography using a 20 L isothermic chamber near the mouth. At the end of each randomized trial, an inspiratory capacity manoeuvre was used to determine end-expiratory lung volume (EELV). EELV increased significantly (P<0.05) with each level of CPAP regardless of oscillation frequency. Fosc also significantly increased with CPAP (P<0.05) and it was correlated with EELV (r=0.7935, P<0.05) in obstructed patients but not in healthy subjects (r=0.125, P=0.343). There were no significant differences in perceived comfort across the levels of CPAP. Significant increases in Fosc with CPAP-induced increases in lung volume were observed, suggesting that CPAP may be useful as a therapeutic adjunct in patients who have obstructive airway disease and who require HFCWO.

Highlights

  • The effectiveness of high-frequency chest wall oscillation (HFCWO) in mucolysis and mucous clearance is thought to be dependant on oscillatory flow rate (Fosc)

  • In patients, end-expiratory lung volume (EELV) increased significantly (P

  • At 10 Hz, EELV averaged 49.0% forced vital capacity (FVC) at 10 cm H2O CPAP compared with 25.8% FVC at 0 cm H2O CPAP

Read more

Summary

Introduction

The effectiveness of high-frequency chest wall oscillation (HFCWO) in mucolysis and mucous clearance is thought to be dependant on oscillatory flow rate (Fosc). OBJECTIVES: To examine effects of continuous positive airway pressure (CPAP) on Fosc at two oscillation frequencies in healthy subjects and patients with airway obstruction. METHODS: Five healthy subjects and six patients with airway obstruction underwent 12 randomized trials of HFCWO (CPAP levels of 0 cm H2O, 2 cm H2O, 4 cm H2O, 6 cm H2O, 8 cm H2O and 10 cm H2O at frequencies of 10 Hz and 15 Hz) within a body plethysmograph, allowing measurements of changes in lung volume. Fosc significantly increased with CPAP (P

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call