Abstract

The concern of warming brought on by extreme solar radiation entering the glazed façade may become serious in Bangladesh, where high-rise buildings now commonly use these systems. This scenario will lead to higher energy usage since there will be a greater requirement for electricity to cool the indoor environment. Determining the effects of the Cavity Depth of Glass facades on the energy consumption of office buildings in Dhaka, Bangladesh, is the primary goal of this study. To establish techniques for optimization, different cavity depths, and other glazed façade system parameters have been proposed. Results were obtained by modelling the variables of the investigation using the computer simulation software EnergyPlus. As per the findings of the study, glazed façade systems in Dhaka may benefit greatly from a cavity depth of 1000 mm combined with bronze laminated glass. The glass façade's thermal performance is enhanced under the ideal cavity system since there is a discernible drop in the building's annual end-use energy of about 12.28 % and a drop in indoor temperature of roughly 2°C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.