Abstract

AbstractA series of mixed-compression hypersonic inlets at different bleeding rates were simulated at different freestream conditions in this paper. The unstart/restart characteristics of hypersonic inlets were analysed and the reasons why the unstart/restart phenomenon is in existence is presented. The unstart/restart characteristics of hypersonic inlets at different bleeding rates were given. The effects of boundary-layer bleeding on the performance parameter (mass-captured coefficient, total-pressure recovery coefficient), starting and restarting Mach number of hypersonic inlets were discussed. In conclusion, boundary-layer bleeding can improve the performance parameter of hypersonic inlets, and can reduce the starting and restarting Mach number, and can broad the operation range of the hypersonic inlet.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.