Abstract

Heat pipe is always bent in the typical application of electronic heat dissipation at high heat flux, which greatly affects its heat transfer performance. The capillary limit of heat transport in the bent micro-grooved heat pipes was analyzed in the vapor pressure drop, the liquid pressure drop and the interaction of the vapor with wick fluid. The bent heat pipes were fabricated and tested from the bending angle, the bending position and the bending radius. The results show that temperature difference and thermal resistance increase while the heat transfer capacity of the heat pipe decreases, with the increase of the bending angles and the bending position closer to the vapor section. However, the effects of bending radius can be ignored. The result agrees well with the predicted equations.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call