Abstract

Effects of ambient humidity and temperature on partial discharge (PD) characteristics in twisted pairs with conventional and nanocomposite enameled magnet wires have been investigated. Measurements of the PD inception voltage (PDIV) and the apparent PD charge were performed by applying an AC sinusoidal waveform voltage of 60 Hz to the twisted pair. The observed PDIV in this study can be classified into the following three behaviors. First, the PDIV in both wires decreases with increasing relative humidity (RH) at low temperature. Secondly, the PDIV in both wires slightly increases when increasing the RH at high temperature. Thus, there is a certain value of the absolute humidity to determine the lowest PDIV in both cases with the conventional and nanocomposite enameled wires. Thirdly, the PDIV in the conventional enameled wire significantly decreases at the RH of 95%, while the decrease rate of that in the nanocomposite enameled wire is relatively small. The observed PD phenomena are discussed in terms of material characterization of the enameled wires such as changes in permittivity due to moisture absorption and wettabilitiy under voltage application.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.