Abstract

With an aim of suppressing the rotating cavitation by cutting back the leading edge alternately, 4-bladed inducers with uneven blade length were designed. Unsteady cavitations were observed through inlet pressure measurements and high-speed video pictures, covering a wide range of flow rate and cavitation number. It was found that, with the alternate cutting back of leading edge, the range of alternate blade cavitation was extended, and the region of rotating cavitation was diminished. However, the cavitation surge occurred instead of the rotating cavitation. In addition, two types of alternate blade cavitation were found as predicted theoretically. One of them is with longer cavities on longer blades, and the other is with longer cavities on shorter blades. Hysteresis in the alternate blade cavitation pattern was observed depending on the increase or decrease of cavitation number at low flow rate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.