Abstract

The routine use of distal filter devices during carotid angioplasty and stent placement (CAS) is controversial. The aim of this study was to analyze their effects on the incidence of new diffusion-weighted imaging (DWI) lesions as surrogate markers for stroke in important subgroups. DWI was performed immediately before and after CAS in 68 patients with and 175 without protection, and patients were further subdivided according to their age or symptom status. The proportion of patients with new ipsilateral DWI lesion(s) was significantly lower after protected versus unprotected CAS (52% versus 68%), as well as in symptomatic patients (56% versus 74%) or those at or younger than 75 years of age (46% versus 67%; all P < .05). Similarly, the total number of lesions was significantly lower after protected versus unprotected CAS (median, 1; interquartile range [IQR], 0-2; versus median, 1; IQR 0-4.75) and in symptomatic patients (median, 1; IQR, 0-3; versus median, 2; IQR, 0-6) or those at or younger than 75 years of age (median, 0; IQR, 0-2; versus median, 1; IQR, 0-4; all P < .05). In contrast, for asymptomatic patients (48% versus 52%; P = .8; median, 0; IQR, 0-2; versus median, 1; IQR, 0-2.5; P = .6) or those older than 75 years of age (73% versus 69%; P = .7; median, 1; IQR, 0-4; versus median, 1.5; IQR, 0-5.75; P = .6), the proportion of patients with new lesion(s) and the total number of these lesions were not significantly different between protected and unprotected CAS. The use of distal filter devices generally reduces the incidence of new DWI lesions; however, this beneficial effect might not necessarily pertain to older and asymptomatic patients.

Highlights

  • AND PURPOSE: The routine use of distal filter devices during carotid angioplasty and stent placement (CAS) is controversial

  • The use of distal filter devices generally reduces the incidence of new diffusion-weighted imaging (DWI) lesions; this beneficial effect might not necessarily pertain to older and asymptomatic patients

  • CAS potentially has the major disadvantage of producing more emboli to the brain,[10] which has led to the development and widespread application of cerebral protection devices aimed at preventing the passage of embolic material into the cerebral vasculature

Read more

Summary

Objectives

The aim of this study was to analyze their effects on the incidence of new diffusion-weighted imaging (DWI) lesions as surrogate markers for stroke in important subgroups. Using this prospective and updated CAS series, the aim of this study was to analyze the effects of cerebral protection devices on the incidence of new DWI lesions in 2 important sub-

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.