Abstract

The effects of surface adsorption of bovine serum albumin (BSA) and human gamma-globulin (HGG) on the tribological performance of a DLC film were investigated using a quartz crystal microbalance with dissipation (QCM-D), a ball-on-disk reciprocating tribometer, and a three-electrode electrochemical cell. The results showed that the wear depth in the BSA solution was higher than that in the HGG solution. In the HGG solution, the HGG-adsorbed layer could act as a lubricating layer and protect the DLC film from wear. The wear volume of DLC film in BSA and HGG mixture solution was higher than that in single HGG solution. This may be because the BSA molecules inhibit the formation of HGG adsorbed layer during sliding.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.