Abstract

This paper investigates the effects of adhesive layer on Lamb wave ultrasound pitch-catch signals that are excited and sensed by piezoelectric wafer transducers bonded on a slender structure. Analytical models were established to simulate the longitudinal and flexural vibrations of the structures separately and parametric studies of the bonding layer properties, i.e. the shear transfer parameter, adhesive thickness, and shear modulus, were performed. The parametric studies indicate that there exists an optimal adhesive layer thickness that generates maximum ultrasound pitch-catch signal for both wave modes. This prediction was subsequently validated by measurements. In addition, an improved match between the measured and simulated pitch-catch signals was achieved by adjusting the adhesive layer parameters.