BackgroundChildren who were only exposed to a mixture of chloromethylisothiazolinone (CMIT) and methylisothiazolinone (MIT) as humidifier disinfectant (HD) components were evaluated for humidifier disinfectant-associated lung injury (HDLI) from 2012. This study was to evaluate the pulmonary function using, impulse oscillometry (IOS) for children exposed to a mixture of CMIT/MIT from HD.MethodsTwenty-four children who were only exposed to a mixture of CMIT/MIT, with no previous underlying disease, were assessed by IOS. Diagnostic criteria for HDLI were categorized as definite, probable, possible, or unlikely. Home visits and administration of a standardized questionnaire were arranged to assess exposure characteristics.ResultsDefinite and probable cases showed higher airborne disinfectant exposure intensity during sleep (32.4 ± 8.7 μg/m3) and younger age at initial exposure (3.5 ± 3.3 months) compared with unlikely cases (17.3 ± 11.0 μg/m3, p = 0.026; 22.5 ± 26.2 months, p = 0.039, respectively). Reactance at 5 Hz was significantly more negative in those with high-density exposure during sleep (mean, -0.463 kPa/L/s vs. low density, -0.296, p = 0.001). The reactance area was also higher with high-density exposure during sleep (mean, 3.240 kPa/L vs. low density, 1.922, p = 0.039). The mean bronchodilator response with high-density exposure was within the normal range for reactance.ConclusionsSignificant peripheral airway dysfunction were found in children with high levels of inhalation exposure to a mixture of CMIT/MIT during sleep. Strict regulation of a mixture of CMIT/MIT exposure were associated with positive effects on lung function of children.

Highlights

  • Isothiazolinones are broad-spectrum biocides that are widely used in many water-based consumer products, including personal hygiene products, perfume, wall paint, and deodorants to prevent growth of microorganisms [1, 2]

  • Significant peripheral airway dysfunction were found in children with high levels of inhalation exposure to a mixture of CMIT/MIT during sleep

  • Strict regulation of a mixture of CMIT/MIT exposure were associated with positive effects on lung function of children

Read more

Summary

Introduction

Isothiazolinones are broad-spectrum biocides that are widely used in many water-based consumer products, including personal hygiene products, perfume, wall paint, and deodorants to prevent growth of microorganisms [1, 2]. Their sterilizing properties are used in humidifier disinfectant (HD) and air conditioning systems [3]. Children who were only exposed to a mixture of chloromethylisothiazolinone (CMIT) and methylisothiazolinone (MIT) as humidifier disinfectant (HD) components were evaluated for humidifier disinfectant-associated lung injury (HDLI) from 2012. This study was to evaluate the pulmonary function using, impulse oscillometry (IOS) for children exposed to a mixture of CMIT/MIT from HD

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.