Abstract

To assess the effectiveness of the intermittent-scanned continuous glucose monitoring (isCGM) system in preventing severe hypoglycemic episodes and in improving glucose parameters and quality of life. Four hundred T1D individuals were enrolled in a prospective real-word study with an intermittently scanned continuous glucose monitoring device during the 12-months follow-up. The primary endpoint was the incidence of severe hypoglycemic events. 82% of subjects were naïve to the use of the device (group A) and 18% were already wearing the system (group B). The cumulative incidence of severe hypoglycemia (SH) at 12 months was 12.06 per 100 person-year (95% CI: 8.35-16.85) in group A and 10.14 (95% CI: 4.08-20.90) in group B without inter-group differences. In group A there was a significant decrease in SH at 12 months compared to 3 months period (p = 0.005). Time in glucose range significantly increased in both groups accompanied with a significant decrease in glucose variability. HbA1c showed a progressive significant time-dependent decrease in group A. The use of the device significantly improved the perceived quality of life. This study confirmed the effectiveness of the isCGM in reducing hypoglycemic risk without glucose deterioration, with potential benefits on adverse outcomes in T1D individuals. ClinicalTrials.gov registration no. NCT04060732.