Abstract

A geoelectric investigation employing vertical electrical soundings (VES) using the Ajayi - Makinde Two-Electrode array and the conventional Schlumberger configuration was carried out in the Main Campus of Ahmadu Bello University (A.B.U.) Zaria with the aim of testing the reliability and effectiveness of the Ajayi-Makinde Two - Electrode array in depth - to - basement determinations. Interpretations of the two-electrode data and the Schlumberger data revealed that the geometry of the bedrock underlying the Main Campus is undulating. The depth – to - basement values for the Ajayi – Makinde Two – Electrode array ranges from 13.0 m in the central part of the study area to about 30.0 m around the southern end while that obtained from the Schlumberger configuration ranges from 11.0 m in the central part of the study area to about 29.0 m in the southern end. Results of the VES interpretation obtained in this work using the Ajayi - Makinde Two - Electrode array have compared very well with those obtained using the Schlumberger array at the same VES stations. The depth – to - basement values obtained in this work have also compared well with those obtained by previous researchers in the area. The Ajayi - Makinde Two - Electrode array is therefore reliable and effective and can be of use as a geoelectric prospecting method.Keywords: Two–Electrode Array, Vertical Electrical Sounding, Depth–to–Basement and “Bulk Resistivity”

Highlights

  • AIM AND OBJECTIVESThere are quite a number of different electrode arrangements used in electrical D.C. resistivity survey

  • Apparao and Roy (1973) and Kumar (1974), worked on a combination which consists of one current electrode and one potential electrode placed at sufficiently large distance that can approximate to infinity from the measuring environment

  • Gupta and Bhattacharya (1963) and Brizzolari and Bernabini (1979), reported on a combination that consists of two current electrodes both of which feed current into the ground with non acting as a return electrode

Read more

Summary

Introduction

AIM AND OBJECTIVESThere are quite a number of different electrode arrangements used in electrical D.C. resistivity survey. The primary aim of this work is to test the reliability and effectiveness of the Ajayi - Makinde two electrode method in depth – to - basement determinations. This aim will be achieved by: Carrying out vertical electrical D.C. resistivity surveys using the Ajayi – Makinde Two - electrode array and followed by the Schlumberger array at the same VES stations.

Objectives
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.