In the current study, we calculated the vaccine volume and amount of dead space in a syringe and needle during ChAdox1-n CoV vaccine administration using the air-filled technique. The aim is to reduce the dead space in syringes and needles in order to administer up to 12 doses per vial. The hypothetical situation uses a vial with a similar size as the ChAdox1-n CoV vial. We used distilled water (6.5 mL) to fill the same volume as five vials of ChAdox1-n CoV. When 0.48 mL of distilled water is drawn according to the number on the side of the barrel, an additional 0.10 mL of air can be used in the dead space of the distilled water in the syringe and needle for 60 doses, which can be divided into an average of 0.5 mL per dose. ChAdox1-n CoV was administered using a 1-mL syringe and 25G needle into 12 doses using this air-filled technique. The volume of the recipient vaccine will increase by 20% and save on the budget for low dead space syringes (LDS).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.