The present study aims to evaluate the effectiveness of externally bonded stainless steel wire mesh (SSWM) in enhancing the shear strength of reinforced concrete (RC) flanged beams with T-shape cross-section. To identify appropriate SSWM as a strengthening material, tension test and bond test are performed on five locally available SSWM. An experimental investigation is conducted to study the behaviour of RC T-beams strengthened by externally bonded 40 × 32 type SSWM under transverse loading. Two beams are considered as control specimen, and four beams are externally strengthened by two different wrapping configurations. All beams are tested under the two-point loading until failure. Results of experimental investigation, in terms of cracking load, ultimate load, deflection, prove the effectiveness of SSWM in shear strengthening of beams. The numerical model of controlled and SSWM strengthened T-beam specimen is also developed using finite element based software ABAQUS to validate experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.