Abstract

The error in prediction of emmetropic intraocular lens power or postoperative refractive error after lens implantation was analyzed in three groups of eyes after posterior chamber lens implantation. Regression line calculation with the SRK equation or with a groupspecific regression was compared with theoretical calculations in unselected, long myopic and short hyperopic eyes. The cut-off length was below 22.0 mm for the short eyes and above 25.9 mm for the long eyes. In the unselected and hyperopic group, there was only a small difference in mean error and error variance when the three calculation methods were compared. In the high myopic group, the range of error increased in all methods. The worst results were obtained with the standard SRK equation because the slope of the regression line in myopic eyes differs from the classical regression line calculated on an average population of implants. Lens calculation in high myopic eyes should therefore be performed with a specific regression line or by theoretical calculation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.