Abstract

MR-guided adaptive radiotherapy (MRgART) treatment sessions at MR-Linac are time-consuming and changes in bladder filling during the session can impact the treatment dosimetry. In this work, we present the procedure implemented in the clinical workflow to stabilize bladder filling during the MR based adaptive radiotherapy sessions and evaluate its effectiveness and the resulting dosimetric impact on the adaptive plan. Twenty-five rectum cancer patients treated at 1.5T MR-Linac with a short course radiotherapy (25 Gy in 5 fractions of 5 Gy each) were included in this retrospective study. Patients were treated with the adapt-to-shape workflow consisting of a plan adaptation based on the MRI acquired in each session and optimized on the corresponding MR-based synthetic CT. Considering the significant interval time between the acquisition of the first daily MRI used for plan adaptation, and the beam delivery, a bladder catheter was used to stabilize the bladder filling; the procedure consists of emptying the bladder and refilling it with a well-known amount of physiological solution before each MRI acquisition. Two MRIs were acquired at each session: the first was used for plan adaptation and the second was acquired while approving the adapted plan, to be rigidly registered with the first to ensure the appropriateness of the isodoses on the ongoing delivery treatment. A total of 125 sessions and 250 MRI images and bladder contours were analyzed; for each fraction, the time interval between the first and second MRI and the corresponding bladder volumes were recorded; the consistency of bladder volumes and shapes along each online session was assessed with the dice similarity index (DSC) and Hausdorff distance (HD); the impact on plan dosimetry was evaluated by comparing target and bladder DVH cut off points of the plan on the two different MRI datasets. The time interval between the first and second MRI, averaged over the 125 sessions is 39.0 min, range (18.6-75.8) min. The changes in bladder volumes, DSC index, HD, and the differences between the bladder and target DVH cut-off points are shown in the table below. The DSC and HD are comparable to inter-observer variability in manual contour segmentation, with an average DSC of 0.91 and average HD of 2.13 mm; the average differences in bladder and target dosimetry remain under 0.63% and 0.10%, respectively. The use of a procedure in the clinical workflow of MRgART to stabilize the bladder filling throughout the online session may be helpful to guarantee the accuracy of the ongoing delivered treatment.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call