Abstract
Objective Emergency medical services (EMS) clinicians are tasked with early fluid resuscitation for patients with sepsis. Traditional methods for prehospital fluid delivery are limited in speed and ease-of-use. We conducted a comparative effectiveness study of a novel rapid infusion device for prehospital fluid delivery in suspected sepsis patients. Methods This pre-post observational study evaluated a hand-operated, rapid infusion device in a single large EMS system from July 2021-July 2022. Prior to device deployment, EMS clinicians completed didactic and simulation-based device training. Data were extracted from the EMS electronic health record. Eligible patients included adults with suspected sepsis treated by EMS with intravenous fluids. The primary outcome was the proportion of patients receiving goal fluid volume (at least 500 mL) prior to hospital arrival. Secondary outcomes included in-hospital mortality, disposition, and length of stay. Multivariable logistic regression was used to compare outcomes between 6-month pre- and post-implementation periods (July-December 2021 and February-July 2022, respectively), adjusting for patient demographics, abnormal prehospital vital signs, and EMS transport interval. Results Of 1,180 eligible patients (552 in the pre-implementation period; 628 in the post-implementation period), the mean age was 72 years old, 45% were female, and 25% were minority race-ethnicity. Median (interquartile range) fluid volume (in mL) increased between the pre- and post-implementation periods (600 [400,1,000] and 850 [500–1,000], respectively). Goal fluid volume was achieved in 70% of pre-implementation patients and 82% of post-implementation patients. In adjusted analysis, post-implementation patients were significantly more likely to receive goal fluid volume than pre-implementation patients (adjusted odds ratio (aOR) 2.00, 95% confidence interval (CI) 1.51–2.66). Pre-post in-hospital mortality was not significantly different (aOR 0.91, 95% CI 0.59–1.39). Conclusion In a single EMS system, sepsis education and introduction of a rapid infusion device was associated with achieving goal fluid volume for suspected sepsis. Further research is needed to assess the clinical effectiveness of infusion device implementation to improve sepsis patient outcomes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.