Abstract

To evaluate the feasibility and short-term effectiveness of three-dimensional (3D) printed titanium-alloy prosthesis reconstruction after the distal tibia tumor segment resection. The clinical data of 6 patients with bone defect after distal tibia tumor segment resection treated with 3D printed titanium-alloy prosthesis reconstruction and tibiotalar joint fusion between January 2020 and December 2021 were retrospectively analyzed. There were 2 males and 4 females; the age ranged from 12 to 35 years, with an average of 18.5 years. Among them, 4 cases were osteosarcoma, 1 case was Ewing sarcoma, and 1 case was giant cell tumor of bone. The Enneking staging was stage ⅡA in 3 cases, stage ⅡB in 2 cases, and stage Ⅲ in 1 case. The disease duration was 2-5 months (mean, 3.2 months). All patients received preoperative neoadjuvant therapy, and patients with osteosarcoma and Ewing sarcoma started chemotherapy at3 weeks after operation. The systemic and local tumor conditions and prosthesis conditions were evaluated regularly after operation. The Musculoskeletal Tumor Society (MSTS) score and the American Orthopaedic Foot and Ankle Society (AOFAS) score were used to evaluate the lower extremity and ankle function. All patients were followed up 8-26 months, with an average of 15.6 months. There was no local recurrence and distant metastasis during the follow-up. The ankle joints of 5 cases were all in 90° functional position at last follow-up, and there was no complication such as prosthesis loosening and fracture; the ankle joint fusion was stable, the local bone ingrowth was good, and the daily activities could be completed, but the ankle range of motion was limited and the ankle joint was stiff. The MSTS score ranged from 22 to 26, with an average of 24, and 3 cases were evaluated as excellent and 2 cases were good; the AOFAS score ranged from 71 to 86, with an average of 80.6, and 4 cases were evaluated as good and 1 case was fair. One patient had severe periprosthetic infection at 2 months after operation, resulting in failure of prosthesis implantation, pain in limb movement, and poor ankle function; MSTS score was 12, AOFAS score was 50, and both were evaluated as poor; distraction osteogenesis was performed after removal of prosthesis and infection control, at present, it was still in the process of distraction osteogenesis, and local osteogenesis was acceptable. Using 3D printed titanium-alloy prosthesis and tibiotalar joint fusion to reconstruct the bone defect after distal tibia tumor segment resection has satisfactory mechanical stability and function, and is one of the effective distal tibial limb salvage methods.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call