Abstract

An endpack design has been developed for the Fermilab Main Injector Dipole. A major part of the design process was the testing of a series of prototype removable endpacks. The magnetic parameters that were tested included the effective length and the field shape variation. This report presents a description of the measurement techniques and the results for the effective length. The final endpack has an effective length at 1500 A (0.29T) of 2.6 {plus_minus} 0.3 mm greater than the steel length, and the change in effective length from 1500 A to maximum current of 9500 A (1.74T) is {minus}1.88 {plus_minus} 0.05 mm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.