Abstract

For CT scan planning, scan projection radiographs (SPR) are used. Tube tension and current for head SPR can be reduced to a minimum because of the small head diameter and because only high-contrast structures need to be visualized for planning. The goal of this study was to investigate SPR of the head in respect to effective doses, the influence of dose-reduction measures, and comparison with conventional x-ray. Entrance doses for default and minimal settings were measured on a LightSpeed Ultra CT scanner and on conventional x-ray equipment. Effective doses for different scanning fields of the head were calculated for an adult, a 10-year-old child, and a neonate by using the commercially available software PCXMC. Depending on projection and technique, SPR effective doses for adults were 1.9-27.7 muSv; for the 10-year-old child, 2.1-31.1 muSv; and for the neonate, 5.2-97.2 muSv. Doses with the tube under the table were 1.3-3.4 times lower. Doses for conventional radiography were higher than SPR doses for adults and partially lower for children. Depending on the scanning technique, effective doses for head SPR can differ up to 17-fold. The dose is significantly reduced by lowering tube voltage and current, by positioning the tube under the table, and by keeping the thyroid out of the scan or by protecting it with a lead collar. Compared with the conventional x-ray technique, SPR doses tend to be lower due to x-ray beam characteristics.

Highlights

  • AND PURPOSE: For CT scan planning, scan projection radiographs (SPR) are used

  • Doses for conventional radiography were higher than SPR doses for adults and partially lower for children

  • SPRs are technically projection radiographs rather than CT scans because they are performed with the tube fixed, usually in an anteroposterior and/or lateral projection

Read more

Summary

Objectives

The goal of this study was to investigate SPR of the head in respect to effective doses, the influence of dose-reduction measures, and comparison with conventional x-ray. The goal of this study was to assess effective doses from head SPR, to evaluate the influence of different scanning practices on dose, and to compare effective doses from SPR with those from corresponding conventional radiography performed with modern x-ray equipment

Methods
Results
Discussion
Conclusion