Abstract
The question discussed in this paper is whether effective dose can reflect the risk to patients from radiological procedures and can be used, for example, to optimise procedures and compare risks of various methods, to define dose constraints, and to estimate the risks to individuals or populations attributed to medical exposures. This report demonstrates that the use of effective dose for patients could be misleading or even wrong due to inappropriate simplifications of the underlying biological mechanisms and inappropriateness of the weighting factors connected with the definition of effective dose for a given patient population. We show that the choice of the most meaningful quantities to express patient exposure depends strongly on the respective situation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.