Abstract

This study examines cooling efficiency, uniformity, and bubble dynamics on a porous surface. We use infrared (IR) thermometry to visualize results of temperature fields and liquid/vapor interfacial dynamics. Porous and non-porous micro-structured surfaces are prepared using soft-lithography and a ceramic precursor, allylhydropolycarbosilane (AHPCS). The surface cavities promote nucleation, and the heat transfer coefficient on the porous surface is approximately 30% higher than that on the non-porous surface. Additionally, the porous surface exhibits a more uniform temperature field with lower spatial and temporal variations than the non-porous surface. Bubble dynamics is visualized via an IR camera through the bottom side of the test specimens using the IR transparent characteristics of the substrate and micro-structures. The porous surface reveals higher nucleation site density and contact line density and lower equivalent bubble diameter when compared with those of the non-porous surface, and this is consistent with more effective and uniform cooling on the porous surface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.