Abstract

This paper describes a detailed study of the flow structure over repeated two-dimensional square ribs on a ground plane for various values of S/D, and the optimum value of S/D to augment the turbulence intensity near the ground plane. The pitch between the centers of two adjoining square ribs was varied at S/D=2, 3, 5, 7, 9, 11, 13 and 17. The time-mean velocity and turbulence intensity were measured by Laser Doppler Velocimeter. The static pressure was measured by Pitot static tubes. As a result, it is concluded that the pitch ratio S/D=9 is optimum to augment the turbulence intensity in the groove between two adjoining square ribs, when the two-dimensional square ribs are aligned on the wall as a heat transfer promoter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.