Abstract
This study is aim to evaluate the natural frequency variation of the scale-down reinforced concrete containment vessel specimen under accelerated corrosion conditions. A plastic ring was sealed around the perimeter of the cylindrical vessel bottom with the 3.5 % NaCl solution to achieve the accelerated corrosion test. Concrete resistivity, open circuit potential, corrosion rate and natural frequencies were tested and discussed in this study. Test results presented that the accelerated corrosion method with a direct 60 voltage applied was a suitable method for estimating and accelerating the concrete vessel specimen. Therefore, the changes in natural frequencies were consistent with the material degradation of the concrete vessel specimen. The natural frequencies decreased with the increasing corrosion rate or decreasing resistivities for the specimen at higher mode, but would be no change for the specimen at the natural frequency of 1st mode.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.