Abstract

Corrosion by molten phases leads to severe corrosion of heat exchangers in waste-to-energy plants. In addition, the presence of heavy metal chlorides in ash deposit increases degradation at low temperature due to the formation of highly corrosive molten phases. In this study, two heat exchanger materials, a low alloy steel (16Mo3) and a nickel based alloy (Inconel 625) were exposed in air to three different synthetic ashes, with various chloride contents, including ZnCl2 at isothermal temperatures of 450 and 650 °C in a muffle furnace. After the test, thickness and mass losses were evaluated on two separate samples, and metallographic cross sections of the specimens were characterized via SEM/EDX analyses. Both measurement results were in good agreement and showed that the corrosion observed on both materials was higher in the presence of zinc chloride in ash at 450 °C than in ashes without heavy metal chloride at 650 °C.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.