Abstract
This paper shows the aerodynamic characteristics at 50% radial section on a rotor blade of 10 m-diameter wind turbine is exposed to wind shear. A sonic wind speed meter and six cupanemometers are installed 1 D upwind of the turbine in order to measure wind profiles. The anemometers at the top, middle and bottom levels are installed at a height of 18.3, 13.3 and 8.3 meters respectively, which correspond with the height of tip at blade top position, hub height, and tip at blade bottom position, respectively. As results of the measurements, the normal force coefficient in strong wind shear condition decreases compared to those for weak wind shear condition. Even if local angle of attack is almost same condition, the normal force coefficient shows differences due to hysteresis effect. Especially, influence is large when not only a height direction but also a horizontal direction has strong wind shear. A remarkable difference appears in the pressure distribution at that condition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.