Abstract

Friction factors were determined for fully developed turbulent flow of mercury in smooth concentric annuli under conditions where either both walls were unwetted, or both were wetted, or the inner wall was wetted and the outer one unwetted. Three radius ratios (r2/r1) were used, i.e., 2.09, 2.78, and 4.00. Unwetted walls gave the lowest friction factors, which were practically independent of the r2/r1 ratio over the limited range tested. The factors were 10 ± 1 percent higher than the commonly accepted values for smooth pipes (at the same Reynolds number). The highest friction factors were obtained with the inner wall wetted and the outer wall unwetted, and the greater the r2/r1 ratio the greater was the effect. For example, at r2/r1 = 4.00, the friction factors were 9.9% greater than for the situation when both walls were unwetted. The wetting conditions affected the location of the radius of maximum velocity (rm); and it was found that the nearer rm approached r2, the higher was the friction factor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.