Abstract

The single-phase diode-bridge converter-based loads have rapidly proliferated in residential areas. In most harmonic studies, the associated harmonic effect usually does not include the harmonic voltage interaction with the harmonic currents of non-linear loads. This interaction can attenuate or amplify the harmonic current injections of such appliances. This study characterises this effect by showing how prevalent harmonic amplification exists under typical voltage conditions experienced in residential areas, and by understanding how the existence of harmonic attenuation or amplification effect is strongly related to the crest shape of the supply voltage. The analytical model of the single-phase diode-bridge converter-based loads is used to explain why and when harmonic attenuation or amplification happens. The implication is that the impacts of the voltage on the currents at each harmonic order are very different. Failing to include this effect can underestimate or overestimate each order of the harmonic currents.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.