Abstract

Eosinophilia in haemodialysis patients probably results from allergy to haemodialysis-related materials, including dialyzer membranes. We examined the effects of vitamin E-bonded dialyzers on eosinophil counts in haemodialysis patients. We enrolled seven patients who were on regular haemodialysis and had sustained eosinophilia. White blood cell, eosinophil, CD4- and CD8-positive lymphocyte counts, and serum interleukin-5 (IL-5) and IgE levels were determined before, 2 and 4 weeks after switching to vitamin E-bonded dialyzers. Eosinophil and CD4-positive lymphocyte counts and serum IL-5 were significantly (P = 0.003, 0.003 and 0.031, respectively) decreased after switching to vitamin E-bonded dialyzers. CD8-positive lymphocyte counts and serum IgE levels were unaltered. Crossover tests in two cases reproduced the higher eosinophilia within 4 weeks after returning to the original non-vitamin E-bonded dialyzer. Vitamin E-bonded dialyzers may ameliorate eosinophilia through a mechanism mediated by a decrease in IL-5 secretion by CD4-positive lymphocytes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.