Abstract

The ability of vibratory acoustic stimulation to shorten the duration of antepartum fetal heart rate monitoring was investigated by a randomized controlled trial. Vibratory acoustic stimulation did not shorten the overall duration of testing. This failure to improve the performance of antepartum monitoring appeared to result from prolonged accelerations, which complicated one third of the tests in which vibratory acoustic stimulation was employed. Further investigation is warranted using less profound methods of fetal stimulation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.