Abstract

Recent numerical simulations of hypersonic double-cone experiments overpredict the heat-transfer rate to the model by about 20%. We present a systematic analysis of the experimental facility and the physical modeling to explainthisdiscrepancy.Nozzlee owe eldsimulationsareusedtoinvestigatetheeffectofvibrationalnonequilibrium in the test section. These simulations show that the vibrational modes of the nitrogen gas freeze near the nozzle throatconditions, resulting inanelevated vibrationaltemperatureinthetestsection. Thislowersthekineticenergy e ux, reducing the heat transfer to the model. The effect of slip boundary conditions is also studied, and it is shown that weak accommodation of vibrational energy at the surface further reduces the heat-transfer rate to the model. The combination of these two effects brings the predicted heat-transfer rate into agreement with the experiments. In addition, weak e ow nonuniformity in the test section is shown to slightly modify the predicted separation zone, further improving the agreement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.