Abstract

Two-phase flow pattern evolvement characteristic of working pair R134a–DMAC as well as the relationship between the bubble absorption height and vibration parameters (amplitude and frequency) were studied experimentally. Results showed that the bubble behavior and two-phase flow patterns became more complicated and disturbed under the vibration state, besides the bubble jolting and disintegration phenomena were observed. Stability of bubble absorption was also influenced by the vibration parameters. The most significant enhancement effectiveness of system vibration to the bubble absorption of R134a–DMAC occurred when amplitude was 0.4 mm and frequency was 25 Hz within the testing conditions. Finally, absorption pressure and temperature, solution flow rate and solution concentration were testified to influence the bubble absorption height and flow patterns under the vibration conditions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call