Abstract

The analysis of the backscattered statistics using the Nakagami parameter is an emerging ultrasound technique for assessing hepatic steatosis and fibrosis. Previous studies indicated that the echo amplitude distribution of a normal liver follows the Rayleigh distribution (the Nakagami parameter m is close to 1). However, using different frequencies may change the backscattered statistics of normal livers. This study explored the frequency dependence of the backscattered statistics in human livers and then discussed the sources of ultrasound scattering in the liver. A total of 30 healthy participants were enrolled to undergo a standard care ultrasound examination on the liver, which is a natural model containing diffuse and coherent scatterers. The liver of each volunteer was scanned from the right intercostal view to obtain image raw data at different central frequencies ranging from 2 to 3.5 MHz. Phantoms with diffuse scatterers only were also made to perform ultrasound scanning using the same protocol for comparisons with clinical data. The Nakagami parameter–frequency correlation was evaluated using Pearson correlation analysis. The median and interquartile range of the Nakagami parameter obtained from livers was 1.00 (0.98–1.05) for 2 MHz, 0.93 (0.89–0.98) for 2.3 MHz, 0.87 (0.84–0.92) for 2.5 MHz, 0.82 (0.77–0.88) for 3.3 MHz, and 0.81 (0.76–0.88) for 3.5 MHz. The Nakagami parameter decreased with the increasing central frequency (r = −0.67, p < 0.0001). However, the effect of ultrasound frequency on the statistical distribution of the backscattered envelopes was not found in the phantom results (r = −0.147, p = 0.0727). The current results demonstrated that the backscattered statistics of normal livers is frequency-dependent. Moreover, the coherent scatterers may be the primary factor to dominate the frequency dependence of the backscattered statistics in a liver.

Highlights

  • Liver fibrosis is a critical factor leading to cirrhosis and hepatocellular carcinoma [1]

  • This study has explored the effect of ultrasound frequency on the envelope statistics based on the Nakagami model and discussed the sources of ultrasound scattering in a human liver

  • The present work demonstrated the frequency dependence of the backscattered statistics of the liver tissues

Read more

Summary

Introduction

Liver fibrosis is a critical factor leading to cirrhosis and hepatocellular carcinoma [1]. Considering the invasiveness and sampling errors of liver biopsy [3,4], imaging-based assessments of hepatic steatosis and fibrosis are gaining scientific and medical interests for screening and characterizing liver diseases. [1H]-MR spectroscopy is presently considered a standard method for the noninvasive evaluation of fatty livers because the obtained value correlates well with the histological fat content of a liver [8,9,10]. These MR-based approaches are expensive and time consuming, complicating clinically routine examinations

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call