Abstract

The piezoelectric signals generated in cancellous bone by ultrasound irradiation were numerically simulated using a piezoelectric finite-difference time-domain method. The changes of the piezoelectric signals with the cancellous bone thickness were investigated with the changes of the transmitted ultrasound signals. In the ultrasound direction of the strong trabecular orientation, two piezoelectric signals could be observed and was associated with the fast and slow waves in the ultrasound signal. The former wave amplitude did not vary with the thickness. The later wave amplitude randomly varied, but not significantly. In the ultrasound direction of the weak trabecular orientation, the piezoelectric signal due to the overlapped fast and slow waves and its multiple reflected wave could be observed. The former wave amplitude did not vary with the thickness. In both ultrasound directions, the local piezoelectric signal generated at the shallow depth of cancellous bone was dominant, which was because of the high ultrasound attenuation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.