Abstract

The ultrasonic shot peening (USP) treatment was adopted to improve the compressive residual stress, microhardness and corrosion resistance of Ti–6Al–4V (TC4) titanium alloy fabricated by selective laser melting (SLM). The optical microscope (OM), scanning electron microscope (SEM), X-ray diffraction (XRD) and hardness test were used to investigate the microstructure evolution. The effect of the USP on electrochemical behaviour of the SLM TC4 alloy in a 3.5 wt. % NaCl solution was studied using potentiodynamic polarization. After USP treatment, compressive residual stress was induced and microhardness significantly increased. Proper USP treatment can effectively improve corrosion resistance of the SLM TC4 alloy, which is manifested by the increase in corrosion potential and decrease in corrosion current density.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.