Abstract
The mean pressure coefficients indicated by several types of static pressure probe and yaw meter have been measured in turbulent flow on the center line of a circular jet where the normal-component RMS turbulent intensity is about 0.24 of the mean velocity, for a range of yaw angles and a range of ratios of tube size to typical eddy size. For mean yaw angles greater than about 10 degrees , yaw meter calibrations differ significantly between turbulent and non-turbulent flow: this is because of the nonlinearity of the calibration at higher yaw angles, which are reached instantaneously. The response of a disc static tube, whose yaw calibration becomes nonlinear at quite small angles, is spectacularly altered by turbulence in the stream, and the use of this device in turbulent flow cannot be recommended.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.