Abstract
Gas ingestion numerical model and rotor-stator (RS) cavity model with rotor vibration are proposed to investigate the effect of rotor disc vibration on the flow characteristics in the RS cavity and gas ingestion. Results show that the sealing effectiveness at the rim seal clearance is increased due to the rotor disc vibration, and the amplitudes of the pressure fluctuation and the radial velocity of the gas ingestion flow at rim seal clearance are reduced. The speed of the Kelvin-Helmholtz vortex is approximately 82.28% of that without rotor vibration. Numerical results reveal that the effect of the rotor vibration on the RS cavity flow covers the whole cavity, the unsteady flow at the low radius region in RS cavity is caused by the vibration rotor disc. The frequency of the pressure oscillation at the low radius region is approximately equal to the vibration frequency of the rotor disc as the periodic variation of the tip clearance shape in the horizontal intake section of sealing air and the induced periodic mass flow rate of inlet sealing air. The flow characteristics in RS cavity are together determined by the rotor vibration parameters and the Kelvin-Helmholtz vortices in rim seal region.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.