Abstract
Procedures for calculating heat losses and temperature are adapted to air tuyeres of blast furnaces. The effect of the thickness and thermal conductivity of the insulation liner on the inner wall of an air tuyere and the air gap between them on the heat losses through the inner wall and the temperatures of the liner and inner wall is analyzed using an Excel linear code. It is shown that the air gap between the liner and the inner wall has a strong effect on the heat losses through the inner wall and its temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.